CH-09MSPHDT-230VI
Slim Ducts provide an inconspicuous solution, hidden in attics and ceiling crawl spaces, without the energy loss associated with central ducted systems. Slim Ducts offer flexibility of installation as the ducts can be directed into separate areas which are collectively controlled by one wall thermostat. For example, one slim duct can be directed to cool and heat hallways, closets, laundry rooms, and bathrooms of a home while the bedrooms themselves are controlled independently. Slim Ducts are available in 9K, 12K, 18K, 24K, 36K, 48K, and 60K Btu/h models.
Standard Features
Cooling capacity (Min/Max) (BTU/h)
9000
SEER
20.5
Unit Net/Gross weight
37.5/48.3
Unit dimensions (W*H*D)
27.56x19.92x7.87
Rated Current Heating
3.8
Rated Current Cooling
3.05
Port Size (Liquid - Gas/Suction)
Φ6.35/Φ9.52(1/4"/3/8")
Operation temperature Indoor heating
62~86
Operation temperature Indoor cooling
62~86
Operation Range - Heating
62~86
Operation Range - Cooling
62~86
Minimum circuit ampacity
1.1
MCA
1.1
Max.fuse
15
Indoor unit packing dimension (W*H*D)
33.86x21.26x11.22
Indoor unit dimension (W*H*D)
27.56x19.92x7.87
Indoor Noise Level H/M/L
38/35/32
Indoor Net/Gross Weight
37.5/48.3
Indoor Air Flow
353/306/271
HSPF5 at 47°F
10
HSPF4 at 47°F
11.5
Heating capacity (Min/Max) (Btu/h)
10000
Heating capacity at 17F
6800
Heating at +17F
6800
ESP Range
0-0.16
EER
13.5
Design pressure
550/340 PSIG
COP at 47°F
3.37
Ambient temperature - Heating (F)
32~86
Ambient temperature - Cooling (F)
62~90
Additional Refrigerant Charge 1/4 liquid line
0.161
CH-12MSPHDT-230VI
Slim Ducts provide an inconspicuous solution, hidden in attics and ceiling crawl spaces, without the energy loss associated with central ducted systems. Slim Ducts offer flexibility of installation as the ducts can be directed into separate areas which are collectively controlled by one wall thermostat. For example, one slim duct can be directed to cool and heat hallways, closets, laundry rooms, and bathrooms of a home while the bedrooms themselves are controlled independently. Slim Ducts are available in 9K, 12K, 18K, 24K, 36K, 48K, and 60K Btu/h models.
Standard Features
Cooling capacity (Min/Max) (BTU/h)
12000
SEER
21.5
Unit Net/Gross weight
37.5/48.3
Unit dimensions (W*H*D)
27.56x19.92x7.87
Rated Current Heating
5.05
Rated Current Cooling
4.4
Port Size (Liquid - Gas/Suction)
Φ6.35/Φ12.7(1/4"/1/2")
Operation temperature Indoor heating
62~86
Operation temperature Indoor cooling
62~86
Operation Range - Heating
62~86
Operation Range - Cooling
62~86
Minimum circuit ampacity
1.1
MCA
1.1
Max.fuse
15
Indoor unit packing dimension (W*H*D)
33.86x21.26x11.22
Indoor unit dimension (W*H*D)
27.56x19.92x7.87
Indoor Noise Level H/M/L
38/36/33.5
Indoor Net/Gross Weight
37.5/48.3
Indoor Air Flow
353/283/177
HSPF5 at 47°F
9
HSPF4 at 47°F
11.5
Heating capacity (Min/Max) (Btu/h)
12000
Heating capacity at 17F
7200
Heating at +17F
7200
ESP Range
0-0.16
EER
12.5
Design pressure
550/340 PSIG
COP at 47°F
3.29
Ambient temperature - Heating (F)
32~86
Ambient temperature - Cooling (F)
62~90
Additional Refrigerant Charge 1/4 liquid line
0.161